Solar DHW heating and central heating backup with solar cylinder SEM-1 and buffer cylinder SPU-2-W
|
|
|
|
1- Collector array 2- Air vent trap 3- Collector sensor 4- Temperature differential control unit SM-2 5- Pump/fitting assembly 6- Pump/fitting assembly extension 7- Fill drain valve 8- Buffer cylinder SPU-2-W 9- Solar circuit cylinder sensor ( buffer cylinder) 10- DHW Cylinder 11- Solar circuit cylinder sensor (DHW) /td> |
12- Mixer Module MM 13- Buffer cylinder sensor 14- Return tempereture sensor 15- Three-way diverter valve 16- Cylinder sensor, heating water 17- Boiler with control R2 18- Cylinder charging pump, heating water 19- Mixing valve motor 20- Mixing valve circuit pump 21- Flow sensor mixing valve circuit |